Supercritical CO2 Fluid Extraction Device Supercritical CO2 Fluid Extraction Device
Supercritical CO2 Fluid Extraction Device Supercritical CO2 Fluid Extraction Device

Supercritical CO2 Fluid Extraction Device

CO2 supercritical extraction is suitable for the extraction and purification of heat-sensitive compounds. Supercritical CO2 extraction is especially suitable for the extraction of fat-soluble, high-boiling point, heat-sensitive substances. It is also suitable for the fine separation of different components, that is, supercritical distillation. Supercritical extraction can provide an inert environment to avoid product oxidation, does not affect the active ingredients of the extract, has fast extraction speed, is non-toxic, non-flammable, safe to use, does not pollute the environment, and has no solvent residue..
Available ModelsSFE Series
  • Supercritical extraction can be performed near room temperature (35-40°C) and under a CO2 gas envelope, effectively preventing the oxidation and escape of heat-sensitive substances. Therefore, the act
  • The use of supercritical extraction is a clean extraction method. Since the whole process does not use organic solvents, there is no residual solvent substance in the extract, thus preventing the pres
  • Extraction and separation are combined into one. When the saturated dissolved CO2 fluid enters the separator, due to the drop in pressure or the change in temperature, the CO2 and the extract quickly
  • CO2 is an inactive gas. No chemical reaction occurs during the extraction process, and it is a non-flammable gas. It is tasteless, odorless, non-toxic and safe;
  • CO2 gas is cheap, has high purity, is easy to prepare, and can be recycled repeatedly in production, thus effectively reducing costs;
  • Pressure and temperature can both become parameters for regulating the extraction process. The purpose of extraction is achieved by changing the temperature and pressure. Substances can also be separa
Download

SPECIFICATIONS

Model

Volume(L)

Pressure

Temperature   Range 

Extraction   mode

LSFE- 120-50-01

1L

50MPa

RT~75

One   extract and two parts circulation type

LSFE- 121-50-01

1L

50MPa

RT~75

One   extraction, two divisions and one column circulation type

LSFE- 120-50-02

2L

50MPa

RT~75

One   extract and two parts circulation type

LSFE- 121-50-02

2L

50MPa

RT~75

One   extraction, two divisions and one column circulation type

LSFE- 121-50-05

5L

50MPa

RT~75

One   extraction, two divisions and one column circulation type

LSFE- 221-50-06

5L   +1L

50MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 221-50-10

10L

50MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 221-40-20

10L+10L

40MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 121-40-25

25L

40MPa

RT~75

One   extraction, two divisions and one column circulation type

LSFE- 221-40-50

25L+25L

40MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 421-40-100

25L*4  

40MPa

RT~75

Four   extractions, two divisions and one column circulation type

LSFE- 221-40-100

50L+50L

40MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 221-40-200

100L+100L

40MPa

RT~75

Two   extractions, two divisions and one column circulation type

LSFE- 221-40-300

150L+150L

40MPa

RT~75

Two   extractions, two divisions and one column circulation type

Models   can be customized according to different pressures and volumes

REQUEST A QUOTE